Skip navigation

Simulation of air puff tonometry test using Arbitrary Lagrangian-Eulerian (ALE) deforming mesh for corneal material characterisation

Simulation of air puff tonometry test using Arbitrary Lagrangian-Eulerian (ALE) deforming mesh for corneal material characterisation

Maklad, Osama ORCID logoORCID: https://orcid.org/0000-0001-6893-2654, Eliasy, Ashkan, Chen, Kai-Jung, Theofilis, Vassilios and Elsheikh, Ahmed (2019) Simulation of air puff tonometry test using Arbitrary Lagrangian-Eulerian (ALE) deforming mesh for corneal material characterisation. International Journal of Environmental Research and Public Health, 17 (1):54. ISSN 1661-7827 (Print), 1660-4601 (Online) (doi:10.3390/IJERPH17010054)

[thumbnail of Publisher VoR]
Preview
PDF (Publisher VoR)
35524_MAKLAD_Simulation_of_air_puff.pdf - Published Version
Available under License Creative Commons Attribution.

Download (28MB) | Preview

Abstract

Purpose: To improve numerical simulation of the non-contact tonometry test by using arbitrary Lagrangian-Eulerian deforming mesh in the coupling between computational fluid dynamics
model of an air jet and finite element model of the human eye. Methods: Computational fluid dynamics model simulated impingement of the air puff and employed Spallart–Allmaras model to capture turbulence of the air jet. The time span of the jet was 30 ms and maximum Reynolds number was Re = 2.3 × 104, with jet orifice diameter 2.4 mm and impinging distance 11 mm. The model of the human eye was analysed using finite element method with regional hyperelastic material variation and corneal patient-specific topography starting from stress-free configuration. The cornea was free to deform as a response to the air puff using an adaptive deforming mesh at every time step of the solution. Aqueous and vitreous humours were simulated as a fluid cavity filled with incompressible fluid with a density of 1000 kg/m3.
Results: Using the adaptive deforming mesh in numerical simulation of the air puff test improved the traditional understanding of how pressure distribution on cornea changes with time of the test. There was a mean decrease in maximum pressure (at corneal apex) of 6.29 ± 2.2% and a development of negative pressure on a peripheral corneal region 2–4 mm away from cornea centre. Conclusions: The study presented an improvement of numerical simulation of the air puff test, which will lead to more accurate intraocular pressure (IOP) and corneal material behaviour estimation. The parametric study showed that pressure of the air puff is different from one
model to another, value-wise and distribution-wise, based on cornea biomechanical parameters.

Item Type: Article
Additional Information: This article belongs to the Special Issue Ocular Biomechanics.
Uncontrolled Keywords: ocular biomechanics; intraocular pressure (IOP); fluid–structure interaction (FSI); arbitrary Lagrangian–Eulerian mesh (ALE)
Subjects: T Technology > TJ Mechanical engineering and machinery
Faculty / School / Research Centre / Research Group: Faculty of Engineering & Science
Faculty of Engineering & Science > School of Engineering (ENG)
Last Modified: 16 May 2022 09:05
URI: http://gala.gre.ac.uk/id/eprint/35524

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year

View more statistics