Skip navigation

Skill assessment in upper limb myoelectric prosthesis users: Validation of a clinically feasible method for characterising upper limb temporal and amplitude variability during the performance of functional tasks

Skill assessment in upper limb myoelectric prosthesis users: Validation of a clinically feasible method for characterising upper limb temporal and amplitude variability during the performance of functional tasks

Thies, Sybille B., Kenney, Laurence P. J., Sobuh, Mohammad, Galpin, Adam, Kyberd, Peter ORCID: 0000-0001-9022-6748, Stine, Rebecca and Major, Mathew J. (2017) Skill assessment in upper limb myoelectric prosthesis users: Validation of a clinically feasible method for characterising upper limb temporal and amplitude variability during the performance of functional tasks. Medical Engineering & Physics, 47. pp. 137-143. ISSN 1350-4533 (Print), 1873-4030 (Online) (doi:https://doi.org/10.1016/j.medengphy.2017.03.010)

[img]
Preview
PDF (Author Accepted Manuscript)
17305 KYBERD_Upper_Limb_Myoelectric_Prosthetic_Users_2017.pdf - Accepted Version

Download (816kB) | Preview

Abstract

Upper limb myoelectric prostheses remain challenging to use and are often abandoned. A proficient user must be able to plan/execute arm movements while activating the residual muscle(s), accounting for delays and unpredictability in prosthesis response. There is no validated, low cost measure of skill in performing such actions. Trial-trial variability of joint angle trajectories measured during functional task performance, linearly normalised by time, shows promise. However, linear normalisation of time introduces errors, and expensive camera systems are required for joint angle measurements.

This study investigated whether trial-trial variability, assessed using dynamic time warping (DTW)of limb segment acceleration measured during functional task performance, is a valid measure of user skill. Temporal and amplitude variability of forearm accelerations were determined in 1) seven myoelectric prosthesis users and six anatomically-intact controls and 2) seven anatomically-intact subjects learning to use a prosthesis simulator over repeated sessions.

1: temporal variability showed clear group differences (p<0.05). 2: temporal variability considerably increased on first use of a prosthesis simulator, then declined with training (both p<0.05). Amplitude variability showed less obvious differences. Analysing forearm accelerations using DTW appears to be a valid low-cost method for quantifying movement quality of upper limb prosthesis use during goal-oriented task performance.

Item Type: Article
Uncontrolled Keywords: Accelerations; Dynamic time warping; Myoelectric prostheses; Upper limb; Variability
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Faculty / School / Research Centre / Research Group: Faculty of Engineering & Science
Faculty of Engineering & Science > School of Engineering (ENG)
Last Modified: 04 Jul 2018 00:38
URI: http://gala.gre.ac.uk/id/eprint/17305

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year

View more statistics