Study with Greenwich  | Student Information  | About Us  | Research  | Contact Us

About GALA

Browse Contents

Guide to Depositing in GALA

For Greenwich Depositing Authors

Quick Search on GALA

Advanced Search

Search the University website

Peptide polarity and the position of arginine as sources of selectivity during positive electrospray ionisation mass spectrometry

Abaye, Daniel A., Pullen, Frank S. and Nielsen, Birthe V. (2011) Peptide polarity and the position of arginine as sources of selectivity during positive electrospray ionisation mass spectrometry. Rapid Communications in Mass Spectrometry, 25 (23). pp. 3597-3608. ISSN 1097-0231 (online)

Full text not available from this repository.
Official URL: http://dx.doi.org/10.1002/rcm.5270

Abstract

Electrospray ionisation (ESI) is a selective process and, for similar sized analytes, the intrinsic properties of the molecules affect the ionisation process and their response. This research sets out to determine the effect of some of these properties in peptides: peptide polarity and the presence of arginine at positions 1 and 4 in the amino acid sequence on the ESI response. Six peptides; molecular mass ranges 1.3–1.6 kDa; substance P (SP) and glutamate fibrinopeptide (GFP) and 3.2–3.7 kDa; calcitonin gene-related peptide (CGRP), vasoactive intestinal peptide (VIP), glucagon-like peptide 1 (GLP1) and defensin human neutropeptide 2 (DHNP2), were investigated. We have demonstrated that in positive ESI, for similar sized peptides and the same charge state, the responsiveness is in the order: Peptides with N or C terminal arginine > most non-polar peptides > least non-polar peptides. Therefore, arginine at the terminal position is a source of selectivity. Data from matrix-assisted laser desorption ionisation (MALDI) analysis supports that of the ESI experiments: Peptides with a terminal arginine residue generated higher signal intensities. Our observations extend our understanding of the ESI process and provide a rational approach to optimising sensitivity of electrospray conditions where a narrow mass range of peptides are poorly chromatographically resolved. This information will provide for a more effective method development process, especially during label-free quantitative determination of peptides extracted in solution.

Item Type: Article
Uncontrolled Keywords: electrospray ionisation (ESI)
Subjects: Q Science > QD Chemistry
R Medicine > RM Therapeutics. Pharmacology
School / Department / Research Groups: School of Science > Department of Pharmaceutical, Chemical & Environmental Sciences
School of Science
Related URLs:
Last Modified: 13 Dec 2011 14:52
URI: http://gala.gre.ac.uk/id/eprint/7049

Actions (login required)

View Item