Skip navigation

Items where Greenwich Author is "Habtay, Dr. Yehdego"

Items where Greenwich Author is "Habtay, Dr. Yehdego"

Group by: Item Type | Date | Funders | Uncontrolled Keywords | No Grouping
Jump to: 3-pole PV-based DC microgrid, 3L-VSC, P&O MPPT | Circuit breakers, Decision making, Maintenance engineering, Witchgear testing, Circuit breaker analysis, Circuit breaker testing, Decision making process, Maintenance activity, Testing industry, Circuit Breaker, DCM, DRM, Dual ground, Vibration | D-STATCOM, DER, I-V characteristic, P-V characteristic, PV irradiance, PV panel, PV-array, PV-grid system distributed energy resource, Distribution static compensator, Grid-connected inverter, Inverter based photovoltaic generator, Low-voltage network power management, Power quality, Reactive power compensation, Solar panel | DC submarine cable, FRT, Matlab, PI-based DC voltage controller, PWM based electromagnetic transient model, Simulink, VSC-HVDC transmission system combined offshore wind integration, Controllable three phase voltage source convertor, Fault ride through capability, Hysteresis controller, Inductive resistive circuit, Modular multilevel converter, Short circuit ratio, Wave farm | DER, PHIL, ancillary service, droop control, power hardware in the loop, voltage regulation, low voltage grid, SOLAR PV | DERs, Ancillary Services, PHIL, Microgrid, Battery Energy Storage System, Solar PV, Wind, Power Quality | EMTP;HVDC power convertors;HVDC power transmission;PI control;offshore installations;power transmission control;power transmission faults;power transmission reliability;substations;voltage control;wave power plants;wind power plants;4-VSC based multiterminal HVDC transmission;EMT;MTDC network;PI-based DC grid voltage control technique;converter statio temporal loss;converter station permanent loss;electromagnetic transient;fault ride through;ground fault;hysteresis simulation analysis;offshore wind farm;transmission loss reduction;wave farm integration;Circuit faults;HVDC transmission;Hysteresis;Power conversion;Voltage control;Wind farms;Fault ride through (FRT);Hysteresis controller;MTDC;PI controller;VSC HVDC | PI, Hysteresis, FRT, VSC, HVDC, MMC | Tank Circuit (TC), Limit-based P&O MPPT, DC-link, PV, DC Microgrid, 3L-VSC; 3-Pole | Tank Circuit (TC), distributed-PWM, DC-link, PV, DC microgrid, VSC, pole | circuit breaker, DCM, DRM, dual ground, vibration | power quality, ancillary services, DER, PHIL, inverters, LV grid, distributed generation (DG), droop control, OLTC, power hardware in the loop (PHIL)
Number of items: 12.

3-pole PV-based DC microgrid, 3L-VSC, P&O MPPT

Giwa, Babatunde ORCID logoORCID: https://orcid.org/0000-0001-5178-072X and Habtay, Yehdego (2019) Multi-voltage level operation of DC loads in 3-pole PV-based DC microgrid. In: The International Conference on Energy and Sustainable Futures (ICESF) 2019. Nottingham Trent University, Nottingham, United Kingdom. ISBN 978-1912253029

Circuit breakers, Decision making, Maintenance engineering, Witchgear testing, Circuit breaker analysis, Circuit breaker testing, Decision making process, Maintenance activity, Testing industry, Circuit Breaker, DCM, DRM, Dual ground, Vibration

Jeyaraj, S.G. and Habtay, Yehdego (2011) Effective and efficient circuit breaker analysis. In: IET Conference on Reliability of Transmission and Distribution Networks (RTDN 2011), 22-24 November 2011, London, UK.

D-STATCOM, DER, I-V characteristic, P-V characteristic, PV irradiance, PV panel, PV-array, PV-grid system distributed energy resource, Distribution static compensator, Grid-connected inverter, Inverter based photovoltaic generator, Low-voltage network power management, Power quality, Reactive power compensation, Solar panel

Oyegoke, Solomon and Habtay, Yehdego (2015) Contribution of inverter based photovoltaic generators to power quality at low voltage. In: Power Engineering Conference (UPEC), 2015 50th International Universities. IEEE, Stoke on Trent, UK, pp. 1-6. ISBN 9781467396820 (doi:10.1109/UPEC.2015.7339824)

DC submarine cable, FRT, Matlab, PI-based DC voltage controller, PWM based electromagnetic transient model, Simulink, VSC-HVDC transmission system combined offshore wind integration, Controllable three phase voltage source convertor, Fault ride through capability, Hysteresis controller, Inductive resistive circuit, Modular multilevel converter, Short circuit ratio, Wave farm

Olowookere, Olusegun, Habtay, Yehdego and Woodhead, Steve (2015) AC fault ride through of modular multilevel converter VSC-HVDC transmission systems. In: Power Engineering Conference (UPEC), 2015 50th International Universities. IEEE, Stoke on Trent, UK, pp. 1-6. ISBN 9781467396820 (doi:10.1109/UPEC.2015.7339823)

DER, PHIL, ancillary service, droop control, power hardware in the loop, voltage regulation, low voltage grid, SOLAR PV

Oyegoke, Solomon, Habtay, Yehdego, Maniatopoulos, Marios, Kotsampopoulos, Panos and Keates, Simoen (2019) Power hardware in the loop and ancillary service for voltage regulation in low voltage grid. In: 2019 54th International Universities Power Engineering Conference (UPEC). IEEE. ISBN 978-1728133492 (doi:10.1109/UPEC.2019.8893578)

DERs, Ancillary Services, PHIL, Microgrid, Battery Energy Storage System, Solar PV, Wind, Power Quality

Oyegoke, Solomon, Habtay, Yehdego, Maniatopoulos, Marios and Keates, Simeon (2020) Frequency and voltage control of island system using power hardware in the loop. In: 2019 8th International Conference on Renewable Energy Research and Applications (ICRERA). IEEE, pp. 587-592. ISBN 978-1728135878 ISSN 2377-6897 (Print), 2572-6013 (Online) (doi:10.1109/ICRERA47325.2019.8996778)

EMTP;HVDC power convertors;HVDC power transmission;PI control;offshore installations;power transmission control;power transmission faults;power transmission reliability;substations;voltage control;wave power plants;wind power plants;4-VSC based multiterminal HVDC transmission;EMT;MTDC network;PI-based DC grid voltage control technique;converter statio temporal loss;converter station permanent loss;electromagnetic transient;fault ride through;ground fault;hysteresis simulation analysis;offshore wind farm;transmission loss reduction;wave farm integration;Circuit faults;HVDC transmission;Hysteresis;Power conversion;Voltage control;Wind farms;Fault ride through (FRT);Hysteresis controller;MTDC;PI controller;VSC HVDC

Olowookere, Olusegun, Skarvelis-Kazakos, Spyros, Habtay, Yehdego and Woodhead, Steve (2014) Fault ride through during loss of converter in a 4-VSC based HVDC transmission. In: Innovative Smart Grid Technologies Conference Europe (ISGT-Europe), 2014 IEEE PES. IEEE, pp. 1-6. (doi:10.1109/ISGTEurope.2014.7028886)

PI, Hysteresis, FRT, VSC, HVDC, MMC

Olowookere, Olusegun, Habtay, Yehdego, Woodhead, Steve and Skarvelis-Kazakos, Spyros (2019) Comparative performance of fault ride through controller in modular multilevel converter based HVDC transmission. In: 54th International Universities Power Engineering Conference (UPEC). IEEE, Bucharest, Romania. ISBN 978-1728133492 (doi:10.1109/UPEC.2019.8893539)

Tank Circuit (TC), Limit-based P&O MPPT, DC-link, PV, DC Microgrid, 3L-VSC; 3-Pole

Giwa, Babatunde ORCID logoORCID: https://orcid.org/0000-0001-5178-072X and Habtay, Yehdego (2019) Transient performance enhancement of tank circuited 3-Pole PV based DC microgrid with limit-based P & O MPPT algorithm. In: 2019 International Conference on Computing, Electronics & Communications Engineering (iCCECE). IEEE, pp. 51-55. ISBN 978-1728121383 (doi:10.1109/iCCECE46942.2019.8941662)

Tank Circuit (TC), distributed-PWM, DC-link, PV, DC microgrid, VSC, pole

Giwa, Babatunde A. ORCID logoORCID: https://orcid.org/0000-0001-5178-072X and Habtay, Yehdego (2019) Tank circuiting of 3-pole PV based DC microgrid for pole-to-pole voltage balancing. In: 2019 54th International Universities Power Engineering Conference (UPEC). IEEE, pp. 1-6. ISBN 978-1728133492 (doi:10.1109/UPEC.2019.8893547)

circuit breaker, DCM, DRM, dual ground, vibration

Gandhi Jeyaraj, S. and Habtay, Yehdego (2011) Effective and efficient circuit breaker analysis. IET 2011 Conference on Reliability of Transmission and Distribution Networks (RTDN 2011). pp. 1-6. (doi:10.1049/cp.2011.0532)

power quality, ancillary services, DER, PHIL, inverters, LV grid, distributed generation (DG), droop control, OLTC, power hardware in the loop (PHIL)

Oyegoke, Solomon, Habtay, Yehdego, Maniatopoulos, Marios, Kotsampopoulos, Panos and Keates, Simeon (2019) Dynamics of inverter droop control and OLTC using power hardware in the loop (PHIL) - (ancillary services supply in low voltage grid). In: The International Conference on Energy and Sustainable Futures (ICESF) 2019: Nottingham Trent University, Nottingham, 9 to 11 September 2019 in collaboration with University Alliance and Doctoral Training Alliance for Energy. Nottingham Trent University: Publications. ISBN 978-1912253012

This list was generated on Fri Dec 27 17:25:49 2024 UTC.